# Kangde Med > Anhui Kangde New Material Technology Co., Ltd. (Kangde Med) is an ISO 13485-certified manufacturer of sterilization monitoring products (chemical indicator tapes and Type 4/5/6 indicator strips for steam, EO, hydrogen peroxide plasma and formaldehyde) and sterilization barrier systems (self-seal and heat-seal pouches, flat and gusseted reels, medical paper and film, EO dialysis pouches), plus oral-care consumables. Based in Hefei, Anhui, China; exporting to 100+ countries; OEM/ODM available. Contact: Jason.wangxiaokang@gmail.com · WhatsApp +86 199 5663 5178 · https://kangdemed.com/contact.html Machine-readable data: https://kangdemed.com/api/products.json · https://kangdemed.com/api/faq.json · https://kangdemed.com/api/site.json · https://kangdemed.com/api/openapi.json · https://kangdemed.com/.well-known/agent-card.json · https://kangdemed.com/sitemap.xml · RSS https://kangdemed.com/feed.xml Key facts: Anhui Kangde New Material Technology Co., Ltd. · founded 2004 · Hefei, Anhui, China · ISO 13485 QMS · products to ISO 11140-1 / ISO 11607-1 / EN 868-5 · CE · OEM/ODM · MOQ per carton · lead time 7–15 working days (OEM 20–30) · exports to 100+ countries. ## Product categories - [Sterilization Monitoring System](https://kangdemed.com/products/sterilization-monitoring-system.html): Chemical indicator tapes and indicator strips (Type 1, Type 4, Type 5 and Type 6) for steam, ethylene oxide (EO), hydrogen peroxide plasma and formaldehyde sterilization — giving CSSD and clinic staff clear, irreversible visual confirmation that packs have been exposed to the process. - [Sterilization Barrier System](https://kangdemed.com/products/sterilization-barrier-system.html): Heat-seal sterilization pouches, self-seal pouches, flat and gusseted sterilization reels, EO dialysis film pouches, and medical coated paper and composite films — manufactured to ISO 11607-1 and EN 868-5 to keep instruments sterile until the point of use. - [Oral Care System](https://kangdemed.com/products/oral-care-system.html): Dental floss, floss sticks for children and adults, interdental brushes and tongue scrapers — produced in the same clean, quality-controlled environment as our medical products, with OEM and private-label packaging available. ## Products - [Steam Indicator Tape](https://kangdemed.com/products/steam-indicator-tape.html): Type 1 process indicator tape for steam sterilization. Adheres firmly to paper, non-woven, SMS and pouches; the yellow diagonal indicator lines turn dark brown/black after exposure to saturated steam. - [EO Indicator Tape](https://kangdemed.com/products/eo-indicator-tape.html): Type 1 process indicator tape for ethylene oxide (EO) sterilization. Indicator lines change from orange to green after exposure to EO gas, identifying processed packs instantly. - [Plasma Indicator Tape](https://kangdemed.com/products/plasma-indicator-tape.html): Type 1 process indicator tape for hydrogen peroxide (H₂O₂) plasma sterilization. Indicator lines change from blue to pink/red after exposure to vaporized hydrogen peroxide. - [Class 4 Steam Indicator Strip](https://kangdemed.com/products/class-4-steam-indicator-strip.html): Type 4 multi-variable chemical indicator strip for steam sterilization. Placed inside every pack, it responds to steam, time and temperature and changes from yellow to black when the critical parameters are reached. - [Class 5 Integrating Indicator Strip](https://kangdemed.com/products/class-5-steam-indicator-strip.html): Type 5 integrating indicator for steam sterilization. Responds to all critical variables (time, temperature, saturated steam) with performance correlated to a biological indicator — the highest level of chemical monitoring for pack release. - [Class 6 Emulating Indicator Strip](https://kangdemed.com/products/class-6-steam-indicator-strip.html): Type 6 emulating indicator designed for a specific steam cycle (e.g. 134 °C / 3.5 min or 121 °C / 15 min). Changes to black only when all critical variables of that cycle are met; custom cycle designs available from 90–140 °C. - [EO Indicator Strip](https://kangdemed.com/products/eo-indicator-strip.html): Type 4 chemical indicator strip for ethylene oxide sterilization. Placed inside the pack, the indicator changes from red to blue when exposed to the stated EO concentration, humidity, temperature and time. - [Plasma Indicator Strip](https://kangdemed.com/products/plasma-indicator-strip.html): Type 4 chemical indicator strip for hydrogen peroxide (H₂O₂) plasma sterilization. Heavy-metal-free indicator placed inside Tyvek® pouches and trays to confirm sterilant penetration. - [Formaldehyde Indicator Strip](https://kangdemed.com/products/formaldehyde-indicator-strip.html): Chemical indicator strip for low-temperature steam-formaldehyde (LTSF) sterilization. Placed inside packs to confirm exposure to formaldehyde at the stated concentration, temperature and time. - [Self-Sealing Sterilization Pouch](https://kangdemed.com/products/self-sealing-sterilization-pouch.html): Medical-grade paper/film pouch with an adhesive closure strip — no heat sealer needed. Dual steam and EO process indicators, three-side burst-resistant seal and a clear film to identify contents. - [Heat-Seal Sterilization Pouch](https://kangdemed.com/products/sterilization-paper-pouch.html): Pre-cut paper/film pouches for heat sealing. Medical-grade 60/70 g/m² paper with blue, white or green composite film, steam, EO and formaldehyde indicators and a three-side burst-resistant seal. - [Sterilization Flat Reel](https://kangdemed.com/products/sterilization-flat-roll.html): Continuous paper/film sterilization reel, 200 m per roll, in 12 widths from 50 mm to 500 mm. Cut to length and heat-seal to package instruments of any size. Steam, EO and formaldehyde indicators printed. - [Sterilization Gusseted Reel](https://kangdemed.com/products/sterilization-gusseted-roll.html): Gusseted paper/film sterilization reel, 100 m per roll, with expandable side pleats for bulky instrument sets, bowls and kits. Widths from 50 mm to 500 mm; steam, EO and formaldehyde indicators printed. - [Medical Coated Paper & Composite Film](https://kangdemed.com/products/medical-paper-and-film.html): Roll-stock packaging materials for form-fill-seal machines: French Arjowiggins coated paper, medical dialysis paper, PET/CPP and PET/PE composite films, and PP/PE or PA/PE blister films for medical device manufacturers. - [EO Dialysis Film Pouch](https://kangdemed.com/products/eto-dialysis-film-pouch.html): Side-seal or middle-seal film pouch with a dialysis paper breathable strip for EO, formaldehyde and irradiation sterilization of finished medical devices. Water-resistant, light-blocking, puncture-resistant; flat or gusseted designs. - [Dental Floss Sticks](https://kangdemed.com/products/floss-sticks.html): Single-use dental floss picks in children's and youth series — rounded edge-free heads, slender handles and cartoon shapes for children; 50-piece boxes, buckets, bamboo-charcoal and fresh-mint versions and 100-piece packs for older users. - [Dental Floss](https://kangdemed.com/products/dental-floss.html): Classical clean dental floss and waxed dental floss series in 50-piece boxes, buckets and individually packed formats, plus 100-piece packs — suitable for dental clinics, retail and private-label supply. - [Interdental Brushes](https://kangdemed.com/products/interdental-brushes.html): I-shaped interdental brushes (from 0.7 mm), L-shaped brushes for back teeth, soft silicone interdental brushes and dual-use toothpick brushes — for cleaning around braces, implants and bridges. - [Tongue Scraper](https://kangdemed.com/products/tongue-scraper.html): Tongue scraper series for removing bacteria and debris from the tongue surface to reduce bad breath — available in several handle designs with custom colours and packaging. ## Solutions by industry - [Hospitals](https://kangdemed.com/solutions/hospitals.html): Hospitals use Kangde Med steam indicator tape to seal and identify every pack, Type 4/5 indicator strips inside packs to confirm sterilant penetration, and ISO 11607 pouches and reels to keep instruments sterile until they reach the patient. - [CSSD / SPD](https://kangdemed.com/solutions/cssd.html): For CSSD/SPD departments Kangde Med supplies the full consumable set: indicator tapes for pack closure, Type 4/5/6 indicator strips for internal monitoring, and pouches and reels in twelve widths so that every instrument set has a correctly sized pack. - [Dental Clinics](https://kangdemed.com/solutions/dental-clinics.html): Dental clinics mostly use Kangde Med self-sealing sterilization pouches (57 × 100 mm to 135 × 260 mm), steam indicator tape and Class 4 indicator strips, sterilized in bench-top autoclaves at 134 °C. - [Laboratories](https://kangdemed.com/solutions/laboratories.html): Laboratories use Kangde Med steam indicator tape and Class 4/5 indicator strips to confirm autoclave cycles for media, glassware and substrate bags, and sterilization reels to package tools and pipettes. - [Medical Device Manufacturers](https://kangdemed.com/solutions/medical-device-manufacturers.html): Kangde Med supplies medical device manufacturers with heat-seal coated paper, dialysis paper, PET/CPP and PET/PE lidding films, PP/PE and PA/PE blister films, EO dialysis film pouches and EO indicators — with custom widths, printing and ISO 11607-1 documentation. ## Articles - [How to Choose the Right Steam Indicator Tape for Your Facility](https://kangdemed.com/blog/how-to-choose-the-right-steam-indicator-tape.html): Learn about the different types of steam indicator tape and the key factors — colour change, adhesion, standards and supplier reliability — that ensure reliable sterilization monitoring. - [Understanding Bowie-Dick Testing in Pre-Vacuum Steam Sterilizers](https://kangdemed.com/blog/understanding-bowie-dick-testing.html): The Bowie-Dick test checks air removal and steam penetration in pre-vacuum sterilizers. Learn when to run it, how to interpret the sheet and what a failed test means for your CSSD. - [Chemical vs Biological Indicators: Roles, Differences and How to Use Them Together](https://kangdemed.com/blog/chemical-vs-biological-indicators.html): Chemical indicators give immediate feedback on process conditions; biological indicators prove lethality. Here is how the ISO 11140-1 indicator types fit together in a monitoring programme. - [Best Practices for Sterile Packaging in Healthcare](https://kangdemed.com/blog/best-practices-for-sterile-packaging.html): Explore proven best practices for sterile packaging, including material selection, pouch sizing, heat sealing, labelling, storage conditions and event-related shelf life. - [What ISO 11607 Means for Healthcare Packaging](https://kangdemed.com/blog/what-iso-11607-means-for-healthcare-packaging.html): ISO 11607 sets the requirements for packaging of terminally sterilized medical devices. This overview explains its two parts, how EN 868-5 relates to it, and what to ask your packaging supplier. - [Optimizing CSSD Workflow: Practical Strategies for Efficiency and Patient Safety](https://kangdemed.com/blog/optimizing-cssd-workflow.html): From standardised pack sizes to indicator colour coding and consumable stock control, these practical steps help CSSD teams process more packs with fewer errors. - [The Importance of Sterilization Monitoring: Physical, Chemical and Biological](https://kangdemed.com/blog/the-importance-of-sterilization-monitoring.html): Sterilization monitoring combines physical, chemical and biological methods to prove that every cycle worked. This guide explains each method, its frequency and the records you need to keep. ## Company - [About](https://kangdemed.com/about.html) - [Quality & Compliance](https://kangdemed.com/quality.html) - [FAQ](https://kangdemed.com/faq.html) - [Resources & Downloads](https://kangdemed.com/resources.html) - [Projects](https://kangdemed.com/projects.html)