Reliable Sterilization Solutions for a Safer Tomorrow

Sterilization Gusseted Reel

Room for Bulky Sets.

Gusseted paper/film sterilization reel, 100 m per roll, with expandable side pleats for bulky instrument sets, bowls and kits. Widths from 50 mm to 500 mm; steam, EO and formaldehyde indicators printed.

  • In Stock
  • Global Supply
  • Trusted Quality
  • OEM/ODM
  • Cut to any length
  • Irreversible indicators
  • Three-side burst-proof seal
  • Clear film — see contents
  • Steam, EO & formaldehyde
A simple indicator. A safer tomorrow.Reliable, easy-to-use sterilization products for every healthcare setting.
Roll Length
100 m per roll
Widths
50, 55, 75, 100, 150, 200, 250, 300, 350, 400, 450, 500 mm
Material
60 g/m² or 70 g/m² medical-grade paper (French Arjowiggins paper available) + blue/white/green medical CPP/PET composite film
Process Indicators
Steam: blue → black · EO: pink → yellow · Formaldehyde: red → green

Product Overview

The gusseted sterilization reel adds folded side pleats to the standard paper/film tube, so the pack can expand to hold bowls, instrument trays, tubing sets and other bulky items without stressing the seals. It is supplied in 100 m rolls in twelve widths and is cut and sealed in the same way as the flat reel.

Key Specifications

Product NameSterilization Gusseted Reel
Roll Length100 m per roll
Widths50, 55, 75, 100, 150, 200, 250, 300, 350, 400, 450, 500 mm
Material60 g/m² or 70 g/m² medical-grade paper (French Arjowiggins paper available) + blue/white/green medical CPP/PET composite film
Process IndicatorsSteam: blue → black · EO: pink → yellow · Formaldehyde: red → green
Sterilization MethodSteam, ethylene oxide, formaldehyde
SealMulti-line side seals, burst-resistant
Manufacturing StandardISO 11607-1, EN 868-5; ISO 13485 quality system; CE
StorageBelow 25 °C and 60 % RH; recommended validity 6 months after sterilization
Sterilization Gusseted Reel detail

Clear Change
Easy to Use
Trusted by Professionals

Features & Benefits

  • Cut to any length
  • Irreversible indicators
  • Three-side burst-proof seal
  • Clear film — see contents
  • Steam, EO & formaldehyde

How to use

  1. Cut the reel to the required length (allow at least 30 mm above the instrument) and seal one end with a heat sealer.
  2. Load the instrument with sharp tips pointing away from the peel side so the pack is not punctured and can be opened safely.
  3. Seal the second end and mark the sterilization date, contents and operator on the film side — never write on the paper.
  4. Process by steam, ethylene oxide or formaldehyde. The printed indicators change colour irreversibly: blue → black for steam, pink → yellow for EO, red → green for formaldehyde.
  5. Store in a clean, dry area below 25 °C and below 60 % RH. Recommended validity: 6 months after sterilization while the pack remains intact.

Applications

Hospital CSSDs and laboratories packaging bulky instrument sets, bowls, kits and tubing.

Packaging & Shipping

Size (inch)Size (mm)PackingCarton (mm)N.W. (kg)G.W. (kg)
2"50 mm × 100 m12 rolls/ctn420 × 220 × 3209.510.5
2.2"55 mm × 100 m12 rolls/ctn420 × 220 × 35010.511.5
3"75 mm × 100 m8 rolls/ctn420 × 220 × 3209.510.5
4"100 mm × 100 m6 rolls/ctn420 × 220 × 3209.510.5
6"150 mm × 100 m4 rolls/ctn420 × 220 × 3209.510.5
8"200 mm × 100 m2 rolls/ctn420 × 220 × 2206.57.5
10"250 mm × 100 m2 rolls/ctn420 × 220 × 27089
12"300 mm × 100 m2 rolls/ctn420 × 220 × 3209.510.5
14"350 mm × 100 m2 rolls/ctn420 × 220 × 3701112
16"400 mm × 100 m2 rolls/ctn420 × 220 × 42012.513.5
18"450 mm × 100 m2 rolls/ctn420 × 220 × 4701415
20"500 mm × 100 m2 rolls/ctn420 × 220 × 52015.516.5
  • Export cartons with lot number and expiry date printed; palletised on request.
  • Sea, air or express — EXW, FOB, CIF or DDP terms. Standard products ship in 7–15 working days.
  • Custom sizes, printing and private-label packaging available for OEM/ODM orders.

Quality Assurance

  • ISO 13485Quality Management System for Medical Devices
  • ISO 11607Packaging for Terminally Sterilized Medical Devices
  • EN 868-5Sealable Pouches & Reels of Porous Materials
  • CECompliant with EU Requirements
  • Batch traceabilityEvery carton carries a lot number linked to raw-material and inspection records
  • Incoming & final inspectionMaterials and finished goods tested before release

Learn more about our quality system · Certificates and test reports are available on request.

Frequently Asked Questions

Which side of the pouch should I write on?

Write on the plastic film side, outside the seal area, or on the sealing flap. Writing on the paper can damage the porous barrier and compromise sterility.

What sterilization methods can the pouch be used with?

Paper/film pouches and reels are suitable for steam (autoclave), ethylene oxide (EO) and formaldehyde sterilization. They are not intended for dry-heat or hydrogen peroxide plasma processes, which require Tyvek® or non-woven materials.